Construction turbo and serial construction

the cards are being reshuffled

Reading time: 3 minutes

The housing shortage in Germany has an enormous social explosive potential and therefore politicians will have to act. The "construction turbo", which will apply from 30.10.2025, is an important step. The new § 246e of the German Building Code allows municipalities to approve residential construction projects in certain cases (densification, brownfield sites, additions, closure of vacant lots, conversion of offices, etc.) without a lengthy preparation or amendment of a development plan. The construction turbo only affects the planning processes, but not the technical standards, subsidies or construction costs. The municipalities must now approve qualified building applications within two months - now the ball is in the companies' court!

The future is serial construction

Serial and modular construction is a successful approach for new and extension buildings to optimize construction costs, cost certainty (guaranteed fixed prices), construction capacities and quality. Most manufacturers use the advantages of timber construction for the room modules (easy processing, high thermal insulation, sustainable material). Industrially manufactured wet rooms are also used in traditional construction methods because only one connection of the supply lines (electrics, water, communication, etc.) is required on site. In countries with other building cultures (Sweden, Estonia, Netherlands), this construction method has therefore the leadership in residential construction.

However, for successful execution without hidden construction defects, know-how and many years of experience with projects and system developments, including the necessary tests and verifications, are required. Supposedly low-cost providers with little experience should therefore be critically assessed – in line with the motto "Inexpensive construction with intelligent solutions instead of cheap construction with poor quality".

Watching individual modules of a prefabricated house being delivered to the construction site and assembled.
Picture 1: Assembly of a ready for occupancy residential building with "almost" finished room modules within a few days (Images: Oikos)

The Federal Association of German Housing and Real Estate Companies developed a framework agreement with 25 providers, to push a successful execution of residential buildings in modular construction.

Modular buildings are an optimal solution and will replace stacking stone on stone or pouring with concrete with its high CO2 emissions.

Therefore, the manufacturers of components should also adapt to this development and gain experience with the processes of this construction method!

 A fire test furnace from ift Rosenheim is shown.
Picture 2: Testing at the ift fire protection centre

Fire and sound insulation

Structural fire protection saves lives and protects property, which is why the requirements for fire resistance and fire behaviour of building products and wooden components are high. The new German “Muster-Holzbauricht-linie” (Model Timber Construction Di-rective) offers new areas of application and the possibility of simpler verifica-tion for timber constructions. The exist-ing test methods according to EN 1363 and EN 1365 have been extended by the test setup according to EN 13381 T7 and have already been successfully carried out at ift Rosenheim with a wide variety of manufacturers.

Examinations and certifications of ift Rosenheim can therefore be used in a wide variety. In the ift fire test centre, which covers more than 3,000 m², tests can be carried out on 5 "fire ovens" on facades, doors, windows, gates, walls, ceilings and columns (with / without loading) and up to a size of 8 m × 5 m.

Room modules usually consist of high-performance and highly thermally insulating composite systems, in which sound insulation is difficult to achieve due to critical resonance frequencies and flank transmissions. For this reason, room modules should be tested and optimised in advance as part of a German type approval. The critical points (joints, joints, wall passages, building services, decouplings, etc.) must be monitored particularly care-fully during quality assurance in the factory and on site. In the ift laboratory "Building Acoustics", it is possible to test all properties on complete room modules without major modifications of the test sample.

Shown here is a ceiling test rig for sound insulation from ift Rosenheim.
Picture 3: Ceiling testing in the building acoustics laboratory of ift Rosenheim
Portraitbild Jürgen Benitz-Wildenburg

Jürgen Benitz-Wildenburg

ift Rosenheim

Jürgen Benitz-Wildenburg is head of the PR & Communication department. As a carpenter, timber construction engineer and marketing expert, he has been working in the timber and window industry in various functions for over 30 years. As a lecturer, speaker and author, he passes on his knowledge.

Solutions related to this topics