Selected topics:
15 articles found
Test – Stick Constructions and Infill Supports
The resistance to positive wind pressure, negative wind pressure and torsion from dead load of stick constructions on curtain wall profiles is tested in a bending test according to DIN EN 16758. In combination with this, the breaking load of supports for infill supports such as glass supports is determined according to DIN EN 17146.
Test – Resistance to Wind Load of Windows + Doors
The resistance to wind load of windows and external doors must be tested according to product standard EN 14351-1 as per EN 12211. The results are given according to classification standard EN 12210.
ift Akademie
The practice-oriented training of employees is a central prerequisite for the success of a company. That is why the motto of the ift Academy is: "Advantage through knowledge". The seminars, specialist degrees, specialist conferences and congresses guarantee competent first-hand knowledge. The lecturers are all specialists in their field and…
Certification – Quality Management DIN EN ISO 9001
As the most successful concept and verification procedure worldwide, certification according to DIN EN ISO 9001 supports and documents a company's quality awareness in the systematic design of its processes at all levels.
Certification – Fire and Smoke Control Door and Shutter Assemblies (Internal use) – QM 305
Due to the standardisation backlog in Europe, interior doors are still regulated nationally. In some countries, a classification report according to EN 13501-2 is required as proof, which requires proof in accordance with product standard EN 16034.
Certification – Door frames for fire-resistant assembly – QM 303
The certification procedure QM 303 ensures the conformity of door frames for fire-resistant assemblies in outdoor applications according to EN 16034-1 or for fire-resistant assemblies in indoor applications according to the general building inspection type approval.
Certification – Internal Doors – QM 326
Doors with the ability to release
Certification – Locks – QM 342
Locks are one of the most important components on a door. Without the right lock, the functions and some performance characteristics according to EN 14351-1 are not given. The interaction between the lock and other components is also crucial.
Certification – Hinges – QM 343
Hinges are one of the most important components on a door. Without the right hinge, the function and some performance characteristics according to EN 14351-1 are not guaranteed. The interaction between the hinge and other components is also crucial.
Certification – Sealants + Sealing Profiles – QM 338
Sealing profiles are among the most important components on a door. Without the right seal, the functions and some performance characteristics according to EN 14351-1 are not given. The interaction between the seal and other components is also crucial.
Certification – Heat Soaked Thermally Toughened Safety Glass – QM 334
Heat soaked thermally toughened soda lime silicate safety glass (TSG-H) according to EN 14179 is subject to CE labelling in so-called System 3. The manufacturer is responsible for the correct implementation of the legal requirements. ift Rosenheim provides support here with certification under private law.
Certification – Thermally Toughened Safety Glass (TSG) – QM 333
Thermally toughened safety glass (TSG) according to EN 12150 is subject to CE marking in so-called System 3. The manufacturer is responsible for the correct implementation of the legal requirements. ift Rosenheim provides support here with certification under private law.