Skip to Content

Testing of acoustics - Measurement of room acoustic parameters - Part 2: Reverberation time in ordinary rooms according to ISO 3382-2

Standards:

ISO 3382-2 - Acoustics - Measurement of room acoustic parameters - Part 2: Reverberation time in ordinary rooms

 

Division building components:

Further details and contact

 

Field of application according to ISO 3382-2 (Chapter 1):

This part of the ISO 3328 specifies methods for measuring reverberation time in rooms. It determines the measurement method, the necessary devices, the required number of measurement points and the method for the evaluation of the data and writing the test report.

 

Requirements according to ISO 3382-2 (Chapter 5):

  • Sound source
  • Microphone
  • Measurement is made in furnished rooms without presence of persons excluding the testing personnel
  • The extraneous noise level is measured and used for the determination of the STI-value
  • Measurement is made along a line that runs across the workspaces
  • The sources and the microphones have to be placed in such a way that they are in height of the heads of the staff

 


Bild