Skip to Content

Testing of variable geometry stay hinges (with or without a friction stay) according to EN 13126-6

 

Standards:

EN 13126-6 - Variable geometry stay hinges (with or without a friction system)
 

Division Building components:

Further information and contact

Scope according to DIN 13126-6 (Chapter 1):

This part of the EN 13126 specifies requirements and test methods for durability, strength, security and function of mechanically operated variable geometry stay hinges (with or without a friction system) for windows.
 

Requirements according to DIN 13126-1 (Chapter 5):

  • Dangerous substances
  • Category of use
  • Durability
  • Mass
  • Fire resistance
  • Safety in use
  • Corrosion resistance
  • Security
  • Applicable part
  • Test sizes
  • Mechanical strength
     

Requirements according to DIN 13126-6 (Chapter 5.3):

  • Pull-in and pull-in abuse test
  • Friction test (where applicable)
  • Obstructed track test
  • Ease of sash movement test
  • Durability pull-in test
  • Simulated negative pressure test
  • Static load test
  • Additional load test